Chimney Inspection: Preventing Collapse

by Nick Gromicko and Rob London
Chimneys are among the heaviest and most structurally vulnerable of all exterior components of
a building. Accidents caused by their collapse can lead to death. A collapse can also cause costly
structural damage to the building and its surroundings. Inspection, maintenance and preparedness are critical safeguards against
chimney collapse.
Wind and other elements may cause
an already weakened chimney to collapse. An elderly man in Britain was crushed by a wind-toppled chimney
as it fell from the roof of the managed-care facility where he lived. This case is, unfortunately, fairly unremarkable,
as such accidents occur often for a variety of reasons -- from weathering and wind, to falling tree limbs and poor design.
Chimneys collapse by the hundreds during major earthquakes, typically
snapping at the roofline. More than half of the homes in Washington State inspected
by the Federal Emergency Management Agency (FEMA) following the Nisqually Earthquake in 2001 sustained chimney damage.
Chimney collapses were widely reported following the massive-magnitude 7.1 earthquake that struck New Zealand
in September 2010.
Earthquake damage and injuries can be caused, in large part, by bricks and
stones as they fall from chimneys onto vehicles, structures and people. These collapses happen suddenly and without warning.
Collapses can also cause implosion-type destruction as the chimney makes its way through the roof and attic,
demolishing part of the living space and injuring occupants below. For these reasons, it is crucial that chimneys, especially
in seismically active regions, be inspected periodically for signs of weakening. Following an earthquake, it is even more vital
that chimneys be inspected for indications of imminent or future collapse.
Chimneys should
be inspected for the following defects:
- mortar between the bricks or stones that crumbles when poked with a screwdriver;
- missing
or insufficient lateral support -- typically, steel straps -- used to tie the chimney to the structure at the roof
and floor levels. Building codes in some seismically active regions require internal and external bracing of chimneys to the
structure;
- mechanical damage to the chimney, such as that caused by falling tree limbs or scaffolding;
- visible tilting or separation from the building. Any gap should be frequently measured to monitor whether it is
increasing; and
- chimney footing defects, including the following:
- undersized
footing, which is footing cast so thin that it breaks, or does not sufficiently extend past the chimney’s base to support its weight;
- deteriorated footing, caused by weathering,
frost, loose or poor-quality construction; and
- poor soil below footing, including eroded, settled
or otherwise weakened soil, frost heaves or expansive clay beneath the footing.

A more thorough inspection performed to the International Phase I Standards of Practice for Inspecting Fireplaces and Chimneys may also be considered.
The following
additional precautions may be taken:
- Attach plywood panels to the roof or above the ceiling joists to act as a barrier between falling masonry
and the roof.
- Strengthen the existing chimney by repairing weak areas.
- Tear down the chimney
and replace it with a flue or a stronger chimney. Keep in mind that tall, slender, masonry chimneys are most vulnerable to
earthquakes, weathering, and other forms of wear. However, even newer, reinforced or metal flue chimneys can sustain
significant damage and require repair.
- Relocate children’s play areas, patios and parking areas
away from a damaged chimney.
- Instruct family members to get away from chimneys during earthquakes.
Homeowners
should contact their local building departments to obtain required permits before starting any significant construction that
may affect the chimney structure and/or its supports.
In addition to collapse hazards,
leaning chimneys can also make using the fireplace dangerous. Hearth cracks, side cracks in the fireplace, openings around
the fireplace, and chimney damage all present the risk that sparks or smoke will enter the living space or building
cavities. Check for evidence of fireplace movement. Following an earthquake, homeowners should have their chimney inspected
before using the fireplace.
Commercial chimney collapses are rare, but they deserve mention
due to the devastation they cause. In one terrible incident in central India, more than 100 workers were
killed when a 900-foot (275-meter) tall chimney collapsed on a construction site. One of the worst construction site disasters
in recent history, the collapse was blamed on heavy rain. While safety standards are generally more stringent outside
of India, commercial chimneys everywhere require inspection.
In summary,
chimneys should be inspected to prevent deadly, expensive collapses.