Insulation R-Value
by Nick Gromicko and Ethan Ward
As energy efficiency has
become an increasing concern among builders and homeowners, the attributes and performance of building materials and components
are being scrutinized more closely. In order to maximize levels of efficiency by examining the details of how each individual
component of a house performs on its own and as part of a dynamic system; very specific properties are measured and taken
into account. This can be especially helpful when trying to select the best building materials for a given application.
R-value is the measurement used when quantifying a specific material’s level of thermal resistance, which is the inverse
of U-value, which measures thermal conductance. R-value is often the standard consideration when discussing the
effectiveness of insulation. Inspectors may want to be familiar with the specifics of R-value ratings, especially
when inspecting insulation and if they also perform energy audits.
How Does
R-Value Relate to Insulation?
Heating and cooling costs account for 50%
to 70% of energy used in an average U.S. home. Inadequate insulation can account for a lot of wasted energy,
so it is important to be sure that insulation installed is doing its job properly. The function of insulation is
to provide resistance to the flow of heat, and R-value is the measure of exactly this attribute for a given material.
A higher R-value equates to higher resistance to heat flow and greater effectiveness in insulating. An insulation material’s
R-value, in conjunction with how and where it is installed, will determine its overall thermal resistance and effectiveness.
Adding the R-values of each layer of material contained in one building component, such as a wall or ceiling with multiple
layers of insulation will help determine the thermal resistance of the whole component. The way the insulation
is installed, as well as other factors, will also affect its thermal resistance.
Important
Factors to Consider When Measuring Thermal Resistance
When considering R-value as a means to determine the
thermal resistance of a building component, there are other factors that must also be taken into account. While R-values
are an excellent guide for comparing the attributes of different insulation products, they apply only when the insulation
is properly installed. For example, if two layers of insulation are smashed into the thickness intended for one
layer, the R-value does not double. Likewise, if a single layer of insulation is compressed during installation, it
will not be as effective. Stuffing batt insulation sized for 5 inches into a 4-inch wall cavity will actually
lower its R-value. Ensuring that insulation is correctly installed will help allow the product’s full benefits
to be realized.
Also important to consider is the fact that even when installed correctly, insulation
affects heat transfer through the insulation itself but not through other materials, such as glass windows and studs.
If there are structural gaps in any building penetrations, even insulation with a high R-value that's installed properly cannot
mitigate heat loss from air leaks. Studs and windows provide a parallel heat conduction path, and insulation between
studs in a wall does not restrict heat flow through the studs. This heat flow is called thermal bridging, and the overall
R-value of the wall will be different from the R-value of the insulation itself.
Calculating and Converting R-Value
The equation used to calculate R-value may be of interest to some inspectors because if
the R-value is known, the equation can also be used to help calculate heat loss. The equation for determining R-value
is as follows:
R-value = temperature difference
x area x time ÷ heat loss
The temperature difference is expressed in degrees Fahrenheit, the area in square
feet, the time in hours, and heat loss in BTUs. Since European R-value uses different units of measure (Celsius, Kelvin,
meters, etc.), it may be helpful to know how to convert a European R-value into a U.S. R-value. This is done by multiplying
the European value by 0.176 and dividing 1 by the result.
The FTC and DOE on R-Value
In the 1970s, the Federal
Trade Commission (FTC) created a rule requiring insulation manufacturers to disclose R-values at the point of sale and
in some ads. This is intended to protect purchasers from false claims made by manufacturers and to create a standard
of comparison for products.
The U.S. Department of Energy (DOE) has
issued recommendations for insulation R-values in new and existing homes. The recommendations are based on a comparison
of the cost for installing insulation versus potential future energy savings. Their recommendations for attics, cathedral
ceilings, walls and floors are generally greater than what is actually required by most current building codes.
R-value ratings are a useful tool, especially when comparing the
effectiveness of insulation products, but understanding a bit about how other factors affect a building component’s
thermal resistance is important if insulation is to be used to its full benefit.
Inspectors who know more about insulation R-values will
be in a better position to utilize this rating most effectively, as well as answer questions that their clients may have about