Mastering Roof Inspections: Underlayment, Part 2

 

by Kenton Shepard and Nick Gromicko

 

The purpose of the series “Mastering Roof Inspections” is to teach home inspectors, as well as insurance and roofing professionals, how to recognize proper and improper conditions while inspecting steep-slope, residential roofs. This series covers roof framing, roofing materials, the attic, and the conditions that affect the roofing materials and components, including wind and hail.

   

TYPES of UNDERLAYMENT

  

There are three basic types of underlayment:

 
  • asphalt-saturated felt;
  • rubberized asphalt; and
  • non-bitumen synthetic.
 

We’ll start by talking about felt.

 ASPHALT-SATURATED FELT

 

Roof_underlayment_2_1.jpg

 

One of the most common types of underlayment used in residential, steep-slope applications is a black, asphalt-saturated felt paper. Felt underlayment may be made from either an organic or fiberglass substrate, although the organic is much more common. It’s called “organic” underlayment because it has a cellulose base.

 

Felt underlayment is water-resistant, not waterproof. It’s available in two thicknesses:  15-pound and 30-pound. Fifteen-pound felt has a perm-rating of about 5, although this number can rise in high-humidity conditions.

 

Thirty-pound felt is more resistant to damage during installation of the roof-covering material and will protect the roof longer if it should somehow become exposed to weather. The difference is obvious, once you see them together. Thirty-pound is much thicker and stiffer. It’s what you see being installed here.

 

INSTALLATION of FELT UNDERLAYMENT

 Slope Limitations

 

Roof_underlayment_2_2.jpg

 In low-slope conditions -- that is, from 2:12 up to 4:12 -- felt courses should overlap a minimum of 19 inches. This will provide a double layer of underlayment across the entire roof. The photo above shows what a low-slope installation looks like.

Roof_underlayment_2_3.jpg

In steep-slope conditions -- that is, 4:12 and steeper -- upper courses of felt underlayment should overlap lower courses by at least 2 inches. Here, you can see the difference between the underlayment overlapped 2 inches on the upper roof, and overlapped 19 inches on the lower, less steep roof.

 

Fastening

 

Roof_underlayment_2_4.jpg
Roof_underlayment_2_5.jpg

Felt is usually fastened with staples, but in high-wind areas, plastic windstrips may be used along the edges to prevent tearing.

 

Roof_underlayment_2_6.jpg

Felt may also be attached in high-wind areas using plastic cap nails, such as those pictured above. Plastic caps offer better wind resistance than staples and also help prevent leakage through the hole made by the fastener.

 

Edge Metal Laps

 

Roof_underlayment_2_7.jpg

Felt underlayment should overlap the edge metal at the eaves and be overlapped by edge metal on the rakes. This is also true for rubberized asphalt underlayment, but not necessarily true for synthetics.

 

FELT UNDERLAYMENT FAILURE

 

Asphalt-saturated felt may fail for a number of reasons.

 

Poor Quality

 

Poor quality is one reason for felt underlayment failure. A number of ASTM standards exist which offer specifications for asphalt-saturated felt.

 

Many manufacturers produce asphalt-saturated paper labeled “Underlayment,” “15-lb.” or “30-lb.,” which does not comply with any standards, and which are often saturated to a lower level than an ASTM-compliant underlayment. These underlayments typically absorb water more readily and fail sooner. Water absorption can cause wrinkling as the product expands. These wrinkles may telegraph through to roof-covering products, such as thinner asphalt shingles.

 

Water from the felt may be absorbed by the roof deck, which can cause problems with expansion and contraction of the deck.

 

You won’t be able to tell by looking whether a product complies with any standards, but if you see what looks like premature failure or distortion of the underlayment, it may be caused by sub-standard underlayment.

 

Loss of Volatiles

 

Over time, volatile compounds in the asphalt will dissipate, and the underlayment will become more fragile and moisture-absorbent. This will happen more quickly when felt is exposed to heat. The source of heat may be a warm climate, a particular type of roof-covering material, poor roof-structure ventilation, or a combination of all these.

 

Roof_underlayment_2_8.jpg
Roof_underlayment_2_9.jpg

UV Exposure

  

Anywhere felt underlayment is exposed directly to sunlight; UV radiation will accelerate its deterioration. These poorly bonded shingles (pictured above) were attached with staples, and the home is located in a high-wind area.

  

No More Asphalt Felt

 

In the future, asphalt-saturated felt underlayment will be used less, and it will probably no longer be installed at all by 2014.  Asphalt is basically the residue left over from the process of refining crude oil.  As the price of oil has increased, refining techniques have been developed that extract the maximum amount of high-quality products from the crude.

 

These techniques, involving the use of “coker units,” leave as residue a powder instead of the sludge from which asphalt is produced. A program has been established in which the asphalt produced each year is limited by the amount of powder or sludge allocated to manufacturers of asphalt shingles and underlayment.

 

Since shingles produce a higher profit margin than underlayment for the amount of asphalt used, most manufacturers are phasing out asphalt-saturated underlayments in favor of synthetic underlayments.

 

Although they fluctuate with raw material prices, as of 2010, prices for felt and synthetic underlayments were similar.

 

 