Mastering Roof Inspections: Attic Ventilation,
Part 2
by Kenton Shepard and Nick Gromicko
The purpose of the series “Mastering Roof Inspections” is to teach home inspectors,
as well as insurance and roofing professionals, how to recognize proper and improper conditions while inspecting steep-slope,
residential roofs. This series covers roof framing, roofing materials, the attic, and the conditions that affect the roofing
materials and components, including wind and hail.
PASSIVE SYSTEMS
Passive vents require no electricity, but their effectiveness often depends on their being properly designed
for a specific home site.
A well-designed passive ventilation system has an intake device
located low in the roof, with an exhaust installed near the ridge.
In a balanced
system, the net opening of the intake will be approximately the same as the net opening of the exhaust.
Soffit Vents
If the system is out of balance, it’s
better to have more ventilation lower in the roof by way of larger intakes.
You may see individual vents each serving
a rafter bay, or continuous vents, as you see here.
As you inspect the attic, make sure
that the soffit vents are not blocked by insulation. This is especially common in attics with blown-in insulation.
If you find blocked vents, comment on them
in your inspection report.
If the insulation is not held back, you
should see baffles installed to create an air space.
It’s important that baffles extend
through to the exterior so that they actually allow air flow into the attic. Once the siding and soffits are complete, you
won’t be able to confirm this visually. Unless you can actually feel air flowing from the baffles, you will not be able
to confirm functional air flow, and you should disclaim it.
Gable Vents
Gable vents are installed in the gabled
ends at opposite ends of the attic. They’re most effective when the vents align with the prevailing winds. This allows
high air pressure on the upwind side of the home to push air into the attic, and low pressure on the downwind side to pull
air out.
When prevailing winds blow perpendicular
to the vents, the gable vents act as both intake and exhaust. Less air exchange takes place and attic ventilation is
not uniform, so it’s less effective.
Roof Vents
Roof vents, sometimes called “turtle”
vents, should be installed near the roof peak. This illustration shows cool air entering the soffit vents.
It rises along the underside of the roof
sheathing and absorbs heat before exiting the attic through the roof vent.
Here,
you see it before and after installation.
Sometimes, the roofers forget to cut the underlayment.
Roof vents do not work unless the underlayment is cut out.
Wind Turbine
Occasionally, you’ll see a turbine vent. Turbines
use a series of specially-shaped vanes that catch wind and spin the turbine. As the vanes spin, they create an area of low
pressure which pulls air from the attic.
While they’re not as effective as ridge vents,
they do provide a low-cost alternative in areas with consistent wind speeds of at least 5 mph.
That’s the power cord for the evaporative cooler you see improperly routed through
the turbine vent into the attic.