Type B and Type L Vent Inspection

by Nick Gromicko and Rob London
Type B Vents
Type B vents are vents suitable only for listed, draft-hood equipped, gas-fired appliances, including most
domestic heating and hot water systems.
They may not be used with any of the following appliances:
- wood-burning appliances, such as fireplaces and wood-burning stoves;
- incinerators;
- oil-fired equipment;
- coal-fired equipment;
- any appliance that burns anything
other than liquid petroleum or natural gas; or
- any appliance that produces flue gasses that exceed
480° F (249° C).
Type B vents must be equipped with their own special chimney caps. If the cap is damaged
or lost, it should not be substituted with something not recommended by the manufacturer. The clearance required from
combustible materials is printed on the flue’s exterior metal surface, and is generally 1 or 2 inches.
Type L Vents
Type L vents are designed for venting approved oil-fired and
natural-gas appliances that produce draft hood flue gasses that do not exceed a temperature of 570º F (299º C),
or 926º F (299º C) for 10 minutes in an over-fire situation. The
minimum clearance from combustible materials is generally 3 inches. Type L vents should not be used to vent coal- or wood-fired
appliances.
It may be difficult to tell the difference between Type L and Type B vents because
they are made from similar components, but the vent type should be clearly printed on the vent. Both are double-walled, although
Type L vents generally have a stainless steel inner wall, while Type B vents do not.
Regardless
of the vent type, InterNACHI inspectors may check for the following defects:

- deterioration of the outer wall, which is likely caused by failure of the inner metal lining;
- violation of roof clearance requirements. All metal vents must terminate at least 2 feet above the roof surface and
anything within 10 feet of the vent, such as the crest of a roof ridge;
- missing components, such
as a chimney cap;
- firestops not installed at either the top or bottom side of the joist where the vent passes through
floors or the roof. The firestop should allow a fire-resistance rating equal to or greater than the floor or roof assemblies
through which the vent passes;
- blocked bird screens, often caused by freezing moisture in cooler
climates;
- crucial joists, rafters or other load-bearing structural members that have been cut to allow for the
vent to pass. Plumbing and electrical lines should also not be disturbed by the vent; and
- whether
the vent is too high or too low. Manufacturers may set minimum and maximum height requirements for the whole vent
assembly, such as the AirJet Type L vent, whose minimum height is 6 feet and maximum height is 30 feet.
Inspectors may recommend that extra corrosion resistance for vents be provided by
a stainless steel cap, stainless steel jacketed pipe sections, or stainless steel or aluminum flashings and storm collars.
They may also recommend that clients use commercially available combustion-enhancing, acid-neutralizing fuel additives to
prevent damage caused to vents from sulfuric acid.
In summary, Type B and Type L vents are designed to vent gasses
from specific types of appliances and under certain conditions.